iks conductivity module for the IKS aquastar system. For the se in fresh and seawater. technical data: high-quality, low-maintenance sensor comprising 4 platinum electrodes 4-conductor method for greatest presicion Measuring range I from 10 µS to 1 mS, resolution 1 µS, switch hysteresis 10 µS Measuring range II from 1mS to 100 mS, resolution 0.1 mS, switch hysteresis 0.2 mS Automatic or manual temperature compensation Automatic calibration with sensor test Up to eight control process can be programmed Upper and lower alarm settings 1 mS and 50 mS calibration solutions included in the set |
 |